INSPECTION
1. INSPECT SHIFT LOCK CONTROL ECU
|
(a) Measure the voltage according to the values in the table below.
HINT:
Do not disconnect the shift lock control ECU connector.
Standard Voltage:
|
Tester Connection
|
Switch Condition
|
Specified Condition
|
|
12 (IG) - 3 (E)
|
Ignition switch ON
|
11 to 14 V
|
|
12 (IG) - 3 (E)
|
Ignition switch off
|
Below 1 V
|
|
6 (STP) - 3 (E)
|
Depress brake pedal
|
11 to 14 V
|
|
6 (STP) - 3 (E)
|
Release brake pedal
|
Below 1 V
|
If the result is not as specified, replace the shift lock control ECU.
|
(b) Measure the resistance according to the value(s) in the table below.
HINT:
Do not disconnect the shift lock control ECU connector.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
8 (E) - Body ground
|
When battery voltage not applied
|
Below 1 Ω
|
If the result is not as specified, replace the shift lock control ECU.
|
(c) Disconnect the shift lock solenoid connector from the shift lock control ECU.
|
(d) Measure the voltage according to the values in the table below.
HINT:
Do not disconnect the shift lock control ECU connector.
Standard Voltage:
|
Tester Connection
|
Switch Condition
|
Specified Condition
|
|
1 (SLS+) - 2 (SLS-)
|
Ignition switch off
|
Below 1 V
|
|
1 (SLS+) - 2 (SLS-)
|
Ignition switch ON
|
Below 1 V
|
|
1 (SLS+) - 2 (SLS-)
|
Ignition switch ON and brake pedal depressed
|
11 to 14 V
|
If the result is not as specified, replace the shift lock control ECU.
2. INSPECT SHIFT LOCK SOLENOID
|
(a) Disconnect the shift lock solenoid connector from the shift lock control ECU.
|
(b) Measure the resistance according to the values in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
1 (SLS+) - 2 (SLS-)
|
When battery voltage not applied
|
101 to 123 Ω
|
|
3 (E2) - 4 (P)
|
Shift position P
|
10 kΩ or higher
|
|
3 (E2) - 4 (P)
|
Shift position not P
|
Below 1 Ω
|
If the result is not as specified, replace the transmission floor shift assembly.
(c) Apply 12 V battery voltage to the shift lock solenoid valve and check that the valve moves and makes an operating noise.
OK:
|
Measurement Condition
|
Specified Condition
|
|
Battery positive (+) → Terminal 1 (SLS+)
Battery negative (-) → Terminal 2 (SLS-)
|
Solenoid moves and makes an operating noise
|
If the result is not as specified, replace the transmission floor shift assembly.
3. INSPECT TRANSMISSION CONTROL SWITCH
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
3 (IG) - 7 (S)
|
Shift position S
|
Below 1 Ω
|
|
3 (IG) - 7 (S)
|
Shift position not S
|
10 kΩ or higher
|
|
2 (SFTU) - 5 (E)
|
Shift lever continuously shifted to "+" position (Up-shift)
|
Below 1 Ω
|
|
2 (SFTU) - 5 (E)
|
Shift position S
|
10 kΩ or higher
|
|
1 (SFTD) - 5 (E)
|
Shift lever continuously shifted to "-" position (Down-shift)
|
Below 1 Ω
|
|
1 (SFTD) - 5 (E)
|
Shift position S
|
10 kΩ or higher
|
If the result is not as specified, replace the transmission floor shift assembly.
|
|